Home › Products › Sample Preparation › XRF Sample Preparation › FX
Equilab · Authorized Distributor in Turkey

Sample Preparation / XRF Sample Preparation

FX

Induction Technology
±1°C Optical Pyrometer
XRF + ICP/AAS
CE Certified
The Fastest and Most Reliable Fusion instrument

The Equilab FX Series generates heat directly inside the Pt/Au crucible via electromagnetic induction. With ±1°C optical pyrometer control and 3–11 minute fusion times, it produces homogeneous glass discs for XRF and fully dissolved solutions for ICP/AAS — no external gas, fume hood, or special infrastructure required.

Equilab FX Series Induction Fusion System
🌡
±1°C
Optical pyrometer temperature accuracy
⚡
3–11 min
Average fusion time
🛡
5+ years
Ceramic holder service life
🔋
90%
Energy conversion efficiency
📋
50
Independently stored fusion programs
🏭
~220°C
Ceramic holder operating temperature
🔬
XRF + ICP
Glass disc and acid solution output
✅
CE
EN 60950-1 · EN 61326 certified
Equilab FX — Induction Fusion Process, Pt/Au Crucible

Heat Generated Directly in the Crucible

An alternating current in the coil creates a magnetic field that induces Foucault (eddy) currents in the Pt/Au crucible. These currents convert to heat via the Joule effect. No external heating element — heat loss to the environment is minimal.

🌡
±1°C Optical Pyrometer Control
Measures infrared radiation from the crucible base without contact. No calibration required; measurement accuracy does not drift over time. 99%+ reproducibility: sample 1 and sample 1,000 receive identical thermal profiles.
👁
Open-Window Full Visibility
The fusion process is monitored in real time. Color change, bubble reduction, viscosity, and homogenization are directly observable. New fusion recipes are optimized in 1–2 runs.
🛡
Low-Cost, Long-Lasting Ceramic Holder.
The holder is exposed to only ~220°C; no thermal shock occurs. Thanks to the long-lasting new generation ceramic holders, the annual cost remains at the level of €500–1000.

What You Wonder About

Typically 3–11 minutes depending on the sample type. Cement requires 5–7 minutes, iron ore 7–10 minutes, and ferroalloys 7–10 minutes. Because the system reaches target temperature instantly, there is no warm-up waiting time.

No. The built-in mini exhaust system with HEPA and activated carbon filters handles sample vapours internally. External installation is optional, not mandatory. The unit operates on a standard laboratory bench.

Yes. By selecting the appropriate program, the system can pour a homogeneous 30–35 mm glass disc for XRF, or dispense the melt directly into HNO₃ or HCl solution for ICP/AAS. Both outputs are obtained from the same instrument with a program change.

Because the holder is exposed to ~220°C, it does not experience thermal shock; its lifespan exceeds 1 year or at least 2000 samples, depending on laboratory conditions and usage. This is significantly longer compared to the 800–1100°C holder temperatures in conventional gas or electric systems. Depending on usage, the annual holder cost remains in the range of €500–1000.

Yes. The ±1°C optical pyrometer control and open-window observation allow full monitoring of the oxidation process. FeCr, FeMn, FeV, FeMo, FeTi, and FeSi samples are prepared with 99%+ homogeneity. The oxidation stage (P1) is controlled directly from the software.

No. A standard 230V/16A outlet and a standard laboratory bench are sufficient. Installation takes 5 minutes. No external specialist, gas connection, reinforced flooring, or dedicated ventilation engineering is required.

Need a Quote?

Contact us for detailed information and pricing options for our instruments. We are here to help with 25 years of experience.